| 16/07a- 16 |
Cuttings
|
454.15
|
3197.35
|
--
|
--
|
.
|
| 16/07a- 16 |
Core #1
|
3790.19
|
3790.55
|
--
|
--
|
well re-boxed (originally curated Aug`81)
|
| 16/07a- 16 |
Core #2
|
3791.71
|
3799.88
|
φ 1.9% (n=8) · Kh 1.2 mD (n=6) · Kv 0.1 mD (n=2) · So 52.5% (n=10) · Sw 29.8% (n=10) · Density 2.53 (n=8) · FSP 5.5 (n=10) · REDWOOD COREX (SERVICES) LIMITED
|
N.P.P.; NO ANALYSIS; S.P. | FNLY INTERBEDDED SLT/CARB. CLAYST.; INTERBEDDED SLT/CARB. CLAYST.; SL. MIC. CARB. CLAYST.
|
--
|
| 16/07a- 16 |
↳ Core Plug #2
|
3791.712
|
--
|
REDWOOD COREX
|
NO ANALYSIS
|
--
|
| 16/07a- 16 |
↳ Plug AKS 1
|
3792.169
|
--
|
So 50.2% · Sw 25.1% · FSP 4.8 · REDWOOD COREX (SERVICES) LIMITED
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKS1
|
3792.169
|
--
|
So 50.2% · Sw 25.1% · FSP 4.8 · REDWOOD COREX
|
N.P.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKS2
|
3793.693
|
--
|
φ 1.9% · Kh 2.4 mD · So 55.3% · Sw 23.8% · Density 2.56 · FSP 5.1 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKS 2
|
3793.693
|
--
|
φ 1.9% · Kh 2.4 mD · So 55.3% · Sw 23.8% · Density 2.56 · FSP 5.1 · REDWOOD COREX (SERVICES) LIMITED
|
FNLY INTERBEDDED SLT/CARB. CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKS3
|
3795.888
|
--
|
φ 1.8% · Kh 0.4 mD · So 67.1% · Sw 25.2% · Density 2.55 · FSP 7.1 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKS 3
|
3795.888
|
--
|
φ 1.8% · Kh 0.3 mD · So 67.1% · Sw 25.2% · Density 2.55 · FSP 7.1 · REDWOOD COREX (SERVICES) LIMITED
|
SL. MIC. CARB. CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKS4
|
3797.656
|
--
|
φ 2.5% · Kv 0.1 mD · So 63.0% · Sw 26.1% · Density 2.52 · FSP 6.9 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKS 4
|
3797.656
|
--
|
φ 2.5% · Kv 0.1 mD · So 63.0% · Sw 26.1% · Density 2.52 · FSP 6.9 · REDWOOD COREX (SERVICES) LIMITED
|
INTERBEDDED SLT/CARB. CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKS5
|
3798.174
|
--
|
φ 1.2% · Kh 0.7 mD · So 26.7% · Sw 49.0% · Density 2.48 · FSP 3.4 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKS 5
|
3798.174
|
--
|
φ 1.2% · Kh 0.7 mD · So 26.7% · Sw 49.0% · Density 2.48 · FSP 3.4 · REDWOOD COREX (SERVICES) LIMITED
|
INTERBEDDED SLT/CARB. CLAYST.
|
--
|
| 16/07a- 16 |
Core #3
|
3800.86
|
3819.14
|
φ 1.9% (n=61) · Kh 1.2 mD (n=42) · Kv 0.1 mD (n=6) · So 42.0% (n=74) · Sw 25.8% (n=76) · Density 2.64 (n=62) · FSP 5.8 (n=76) · REDWOOD COREX (SERVICES) LIMITED
|
N.P.P.; S.P. | BNDED FN. SLT/CARB. CLAYST W/SL IRON.; BNDED. CALC. SLT/CLAY.; BNDED. CALC. SLT/CLAY. PLUS CARB. MATERIAL.; BNDED. CLAY & CALC. SLT.; BNDED. SLT/CLAYST.; CARB. CLAYST. V.FN.SS LAMINATIONS; CARB. CLAYST. W/ FN. CALC. SS LAMINATIONS; CARB. CLAYST. W/CALC. CMT'D V. FN. SS BNDS.; CLAYST. W/SLIGHTLY CALC. SLT. BND.; FN. SIL. CMT'D SS W/ LOAD STRUCTURES & CLAYST. BNDS.; FN. SLT. W/EXT. CALC. CMT. & FN. CARB. CLAY LAMINATIONS; FN. SS. W./EXT. CALC. CMT.; FNLY BNDED. CARB. SLT/CLAY.; FNLY INTERBEDDED V. FN.SS/SLT./ CARB. CLAY; FNLY LAMINATED SLT/CLAY; LAMINATED CARB. CLAYST. W/SLT.; LAMINATED V. FN. SS/SLT/CLAYST.; LAMINATED/FLASERED V/FN. SS/ SLT/CLAYST.; PLUG SAMPLE: ALMOST TOTAL PYRITE.; V. FNLY LAMINATED FN. SLT. & CLAY; V.FN. SLT W/EXTREME CALC. CMT. SL./CARB. MAT.; V.FN. SS/EXT. CALC. CMT. AND V. THIN CLAYST. BNDS.
|
--
|
| 16/07a- 16 |
↳ Plug AKT1
|
3801.374
|
--
|
φ 7.7% · Kv 0.0 mD · So 54.9% · Sw 27.4% · Density 2.51 · FSP 8.5 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 1
|
3801.374
|
--
|
φ 7.7% · Kv 0.0 mD · So 54.9% · Sw 27.4% · Density 2.51 · FSP 8.5 · REDWOOD COREX (SERVICES) LIMITED
|
FNLY INTERBEDDED V. FN.SS/SLT./ CARB. CLAY
|
--
|
| 16/07a- 16 |
↳ Plug AKT 2
|
3801.923
|
--
|
φ 2.0% · So 49.1% · Sw 22.3% · Density 2.56 · FSP 6.9 · REDWOOD COREX (SERVICES) LIMITED
|
FNLY INTERBEDDED V. FN.SS/SLT./ CARB. CLAY
|
--
|
| 16/07a- 16 |
↳ Plug AKT2
|
3801.923
|
--
|
φ 2.0% · So 49.1% · Sw 22.3% · Density 2.56 · FSP 6.9 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 3
|
3802.289
|
--
|
φ 2.0% · So 23.0% · Sw 13.8% · Density 2.53 · FSP 3.2 · REDWOOD COREX (SERVICES) LIMITED
|
CARB. CLAYST. V.FN.SS LAMINATIONS
|
--
|
| 16/07a- 16 |
↳ Plug AKT3
|
3802.289
|
--
|
φ 2.0% · So 23.0% · Sw 13.8% · Density 2.53 · FSP 3.2 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKT4
|
3802.593
|
--
|
φ 2.3% · So 34.1% · Sw 17.0% · Density 2.58 · FSP 3.7 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 4
|
3802.593
|
--
|
φ 2.3% · So 34.1% · Sw 17.0% · Density 2.58 · FSP 3.7 · REDWOOD COREX (SERVICES) LIMITED
|
CARB. CLAYST. W/CALC. CMT'D V. FN. SS BNDS.
|
--
|
| 16/07a- 16 |
↳ Plug AKT5
|
3803.142
|
--
|
So 60.2% · Sw 26.7% · FSP 8.9 · REDWOOD COREX
|
N.P.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 5
|
3803.142
|
--
|
So 60.2% · Sw 26.7% · FSP 8.9 · REDWOOD COREX (SERVICES) LIMITED
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT 6
|
3803.599
|
--
|
φ 0.7% · So 47.1% · Sw 32.1% · Density 2.53 · FSP 7.3 · REDWOOD COREX (SERVICES) LIMITED
|
CARB. CLAYST. W/ FN. CALC. SS LAMINATIONS
|
--
|
| 16/07a- 16 |
↳ Plug AKT6
|
3803.599
|
--
|
φ 0.7% · So 47.1% · Sw 32.1% · Density 2.53 · FSP 7.3 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 7
|
3804.117
|
--
|
φ 1.3% · So 22.2% · Sw 26.7% · Density 2.56 · FSP 3.5 · REDWOOD COREX (SERVICES) LIMITED
|
CARB. CLAYST. W/ FN. CALC. SS LAMINATIONS
|
--
|
| 16/07a- 16 |
↳ Plug AKT7
|
3804.117
|
--
|
φ 1.3% · So 22.2% · Sw 26.7% · Density 2.56 · FSP 3.5 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKT8
|
3804.818
|
--
|
φ 0.5% · Kh 0.1 mD · Kv 0.1 mD · So 46.9% · Sw 28.9% · Density 2.67 · FSP 8.6 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT 8
|
3804.818
|
--
|
φ 0.5% · Kh 0.1 mD · Kv 0.1 mD · So 46.9% · Sw 28.9% · Density 2.67 · FSP 8.6 · REDWOOD COREX (SERVICES) LIMITED
|
V.FN. SS/EXT. CALC. CMT. AND V. THIN CLAYST. BNDS.
|
--
|
| 16/07a- 16 |
↳ Plug AKT9
|
3805.215
|
--
|
So 39.3% · Sw 34.4% · FSP 9.4 · REDWOOD COREX
|
N.P.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 9
|
3805.215
|
--
|
So 39.3% · Sw 34.4% · FSP 9.4 · REDWOOD COREX (SERVICES) LIMITED
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT10
|
3805.337
|
--
|
φ 1.0% · Kh 0.1 mD · So 35.5% · Sw 29.6% · Density 2.70 · FSP 5.5 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT 10
|
3805.337
|
--
|
φ 1.0% · Kh 0.1 mD · So 35.5% · Sw 29.6% · Density 2.70 · FSP 5.5 · REDWOOD COREX (SERVICES) LIMITED
|
FN. SS. W./EXT. CALC. CMT.
|
--
|
| 16/07a- 16 |
↳ Plug AKT11
|
3805.58
|
--
|
φ 0.7% · Kh 0.1 mD · Sw 7.4% · Density 2.68 · FSP 2.2 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT 11
|
3805.58
|
--
|
φ 0.7% · Kh 0.1 mD · So 0.0% · Sw 7.4% · Density 2.68 · FSP 2.2 · REDWOOD COREX (SERVICES) LIMITED
|
FN. SS. W./EXT. CALC. CMT.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 12
|
3806.342
|
--
|
So 52.9% · Sw 31.0% · FSP 9.7 · REDWOOD COREX (SERVICES) LIMITED
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT12
|
3806.342
|
--
|
So 52.9% · Sw 31.0% · FSP 9.7 · REDWOOD COREX
|
N.P.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 13
|
3806.8
|
--
|
φ 3.5% · Kh 0.8 mD · So 48.4% · Sw 36.5% · Density 2.60 · FSP 6.6 · REDWOOD COREX (SERVICES) LIMITED
|
LAMINATED/FLASERED V/FN. SS/ SLT/CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKT13
|
3806.8
|
--
|
φ 3.5% · Kh 0.8 mD · So 48.4% · Sw 36.5% · Density 2.60 · FSP 6.6 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT 14
|
3807.348
|
--
|
φ 3.9% · Kh 0.6 mD · So 36.2% · Sw 36.2% · Density 2.64 · FSP 5.2 · REDWOOD COREX (SERVICES) LIMITED
|
LAMINATED V. FN. SS/SLT/CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKT14
|
3807.348
|
--
|
φ 3.9% · Kh 0.6 mD · So 36.2% · Sw 36.2% · Density 2.64 · FSP 5.2 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT15
|
3807.805
|
--
|
So 42.9% · Sw 26.8% · FSP 5.7 · REDWOOD COREX
|
N.P.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 15
|
3807.805
|
--
|
So 42.9% · Sw 26.8% · FSP 5.7 · REDWOOD COREX (SERVICES) LIMITED
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT16
|
3808.354
|
--
|
Kh 0.1 mD · So 54.7% · Sw 27.4% · Density 3.99 · FSP 1.0 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT 16
|
3808.354
|
--
|
φ 1.0% · Kh 0.1 mD · So 54.7% · Sw 27.4% · Density 3.99 · FSP 8.1 · REDWOOD COREX (SERVICES) LIMITED
|
PLUG SAMPLE: ALMOST TOTAL PYRITE.
|
--
|
| 16/07a- 16 |
↳ Plug AKT17
|
3808.659
|
--
|
φ 1.1% · So 63.1% · Sw 25.3% · Density 2.50 · FSP 7.5 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 17
|
3808.659
|
--
|
φ 1.1% · So 63.1% · Sw 25.3% · Density 2.50 · FSP 7.5 · REDWOOD COREX (SERVICES) LIMITED
|
FNLY BNDED. CARB. SLT/CLAY.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 18
|
3809.025
|
--
|
φ 1.4% · Kh 0.4 mD · So 47.6% · Sw 29.7% · Density 2.59 · FSP 5.4 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED. CALC. SLT/CLAY.
|
--
|
| 16/07a- 16 |
↳ Plug AKT18
|
3809.025
|
--
|
φ 1.4% · Kh 0.4 mD · So 47.6% · Sw 29.7% · Density 2.59 · FSP 5.4 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT19
|
3809.756
|
--
|
φ 2.3% · So 54.9% · Sw 27.5% · Density 2.57 · FSP 7.4 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 19
|
3809.756
|
--
|
φ 2.3% · So 54.9% · Sw 27.5% · Density 2.57 · FSP 7.4 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED. CALC. SLT/CLAY. PLUS CARB. MATERIAL.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 20
|
3810.244
|
--
|
φ 1.8% · Kh 0.6 mD · So 52.9% · Sw 28.7% · Density 2.55 · FSP 7.1 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED. CALC. SLT/CLAY.
|
--
|
| 16/07a- 16 |
↳ Plug AKT20
|
3810.244
|
--
|
φ 1.8% · Kh 0.6 mD · So 52.9% · Sw 28.7% · Density 2.55 · FSP 7.1 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT21
|
3810.762
|
--
|
So 55.3% · Sw 23.0% · FSP 6.7 · REDWOOD COREX
|
N.P.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 21
|
3810.762
|
--
|
So 55.3% · Sw 23.0% · FSP 6.7 · REDWOOD COREX (SERVICES) LIMITED
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT22
|
3811.189
|
--
|
φ 0.7% · Kh 0.1 mD · So 43.6% · Sw 37.5% · Density 2.55 · FSP 6.6 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT 22
|
3811.189
|
--
|
φ 0.7% · Kh 0.1 mD · So 43.6% · Sw 37.5% · Density 2.55 · FSP 6.6 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED. CALC. SLT/CLAY.
|
--
|
| 16/07a- 16 |
↳ Plug AKT23
|
3811.646
|
--
|
φ 1.0% · Kh 0.7 mD · So 37.2% · Sw 32.5% · Density 2.55 · FSP 6.5 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT 23
|
3811.646
|
--
|
φ 1.0% · Kh 0.7 mD · So 37.2% · Sw 32.5% · Density 2.55 · FSP 6.5 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED. CALC. SLT/CLAY.
|
--
|
| 16/07a- 16 |
↳ Plug AKT24
|
3812.073
|
--
|
So 43.0% · Sw 27.7% · FSP 6.7 · REDWOOD COREX
|
N.P.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 24
|
3812.073
|
--
|
So 43.0% · Sw 27.7% · FSP 6.7 · REDWOOD COREX (SERVICES) LIMITED
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT25
|
3812.56
|
--
|
φ 0.5% · Kh 0.1 mD · So 54.4% · Sw 29.7% · Density 2.68 · FSP 6.4 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT 25
|
3812.56
|
--
|
φ 0.5% · Kh 0.1 mD · So 54.4% · Sw 29.7% · Density 2.68 · FSP 6.4 · REDWOOD COREX (SERVICES) LIMITED
|
V.FN. SLT W/EXTREME CALC. CMT. SL./CARB. MAT.
|
--
|
| 16/07a- 16 |
↳ Plug AKT26
|
3812.926
|
--
|
φ 0.4% · Kh 0.1 mD · Sw 19.9% · Density 2.67 · FSP 1.6 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT 26
|
3812.926
|
--
|
φ 0.4% · Kh 0.1 mD · So 0.0% · Sw 19.9% · Density 2.67 · FSP 1.6 · REDWOOD COREX (SERVICES) LIMITED
|
V.FN. SLT W/EXTREME CALC. CMT. SL./CARB. MAT.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 27
|
3813.353
|
--
|
φ 0.4% · Kh 0.3 mD · So 39.8% · Sw 26.5% · Density 2.66 · FSP 4.6 · REDWOOD COREX (SERVICES) LIMITED
|
FN. SLT. W/EXT. CALC. CMT. & FN. CARB. CLAY LAMINATIONS
|
--
|
| 16/07a- 16 |
↳ Plug AKT27
|
3813.353
|
--
|
φ 0.4% · Kh 0.3 mD · So 39.8% · Sw 26.5% · Density 2.66 · FSP 4.6 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT28
|
3814.267
|
--
|
φ 0.7% · Kh 0.2 mD · Kv 0.1 mD · So 28.8% · Sw 12.5% · Density 2.52 · FSP 2.5 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT 28
|
3814.267
|
--
|
φ 0.7% · Kh 0.2 mD · Kv 0.1 mD · So 28.8% · Sw 12.5% · Density 2.52 · FSP 2.5 · REDWOOD COREX (SERVICES) LIMITED
|
V. FNLY LAMINATED FN. SLT. & CLAY
|
--
|
| 16/07a- 16 |
↳ Plug AKT 29
|
3814.572
|
--
|
So 53.4% · Sw 16.0% · FSP 4.0 · REDWOOD COREX (SERVICES) LIMITED
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT29
|
3814.572
|
--
|
So 53.4% · Sw 16.0% · FSP 4.0 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT 30
|
3815.121
|
--
|
φ 0.6% · So 20.2% · Sw 26.9% · Density 2.58 · FSP 2.4 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED. SLT/CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKT30
|
3815.121
|
--
|
φ 0.6% · So 20.2% · Sw 26.9% · Density 2.58 · FSP 2.4 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKT31
|
3815.639
|
--
|
φ 2.1% · Kh 1.1 mD · So 25.1% · Sw 16.7% · Density 2.61 · FSP 1.9 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT 31
|
3815.639
|
--
|
φ 2.1% · Kh 1.1 mD · So 25.1% · Sw 16.7% · Density 2.61 · FSP 1.9 · REDWOOD COREX (SERVICES) LIMITED
|
CLAYST. W/SLIGHTLY CALC. SLT. BND.
|
--
|
| 16/07a- 16 |
↳ Plug AKT32
|
3816.096
|
--
|
φ 1.2% · Kh 0.8 mD · So 45.5% · Sw 26.0% · Density 2.61 · FSP 4.9 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT 32
|
3816.096
|
--
|
φ 1.2% · Kh 0.8 mD · So 45.5% · Sw 26.0% · Density 2.61 · FSP 4.9 · REDWOOD COREX (SERVICES) LIMITED
|
FNLY LAMINATED SLT/CLAY
|
--
|
| 16/07a- 16 |
↳ Plug AKT 33
|
3816.614
|
--
|
φ 2.7% · So 44.3% · Sw 31.6% · Density 2.64 · FSP 4.4 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED. CLAY & CALC. SLT.
|
--
|
| 16/07a- 16 |
↳ Plug AKT33
|
3816.614
|
--
|
φ 2.7% · So 44.3% · Sw 31.6% · Density 2.64 · FSP 4.4 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKT34
|
3817.102
|
--
|
φ 0.7% · Kh 0.2 mD · So 40.6% · Sw 30.4% · Density 2.54 · FSP 6.2 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT 34
|
3817.102
|
--
|
φ 0.7% · Kh 0.2 mD · So 40.6% · Sw 30.4% · Density 2.54 · FSP 6.2 · REDWOOD COREX (SERVICES) LIMITED
|
LAMINATED CARB. CLAYST. W/SLT.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 35
|
3817.62
|
--
|
φ 0.5% · Kh 0.1 mD · So 43.9% · Sw 27.0% · Density 2.57 · FSP 4.7 · REDWOOD COREX (SERVICES) LIMITED
|
LAMINATED CARB. CLAYST. W/SLT.
|
--
|
| 16/07a- 16 |
↳ Plug AKT35
|
3817.62
|
--
|
φ 0.5% · Kh 0.1 mD · So 43.9% · Sw 27.0% · Density 2.57 · FSP 4.7 · REDWOOD COREX
|
N.P.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKT 36
|
3818.077
|
--
|
φ 2.4% · Kh 1.2 mD · So 38.7% · Sw 19.3% · Density 2.57 · FSP 4.9 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED FN. SLT/CARB. CLAYST W/SL IRON.
|
--
|
| 16/07a- 16 |
↳ Plug AKT36
|
3818.077
|
--
|
φ 2.4% · Kh 1.2 mD · So 38.7% · Sw 19.3% · Density 2.57 · FSP 4.9 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT 37
|
3818.595
|
--
|
φ 0.6% · Kh 0.2 mD · So 34.1% · Sw 31.0% · Density 2.58 · FSP 5.0 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED FN. SLT/CARB. CLAYST W/SL IRON.
|
--
|
| 16/07a- 16 |
↳ Plug AKT37
|
3818.595
|
--
|
φ 0.6% · Kh 0.2 mD · So 34.1% · Sw 31.0% · Density 2.58 · FSP 5.0 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT38
|
3819.053
|
--
|
φ 11.4% · Kh 16.7 mD · So 38.4% · Sw 11.2% · Density 2.62 · FSP 13.0 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKT 38
|
3819.053
|
--
|
φ 11.4% · Kh 16.7 mD · So 38.4% · Sw 11.2% · Density 2.62 · FSP 13.0 · REDWOOD COREX (SERVICES) LIMITED
|
FN. SIL. CMT'D SS W/ LOAD STRUCTURES & CLAYST. BNDS.
|
--
|
| 16/07a- 16 |
Core #4
|
3819.2
|
3838.16
|
φ 2.0% (n=74) · Kh 11.4 mD (n=52) · Kv 0.1 mD (n=8) · So 29.0% (n=76) · Sw 30.8% (n=76) · Density 2.65 (n=74) · FSP 4.1 (n=76) · REDWOOD COREX (SERVICES) LIMITED
|
N.P.P.; S.P. | BNDED CALC. V.FN. SS/CARB. CLAY.; BNDED FN. SLT/CLAYST.; BNDED SLT/CLAY & FN. BRECCIA; BNDED SLT/CLAY W/BRECCIA MAT.; BNDED V. FN. SLT. CARB. CLAYST.; BNDED V/FN. SS & SLT/CLAY; BNDED V/FN. SS/SLT/CLAY; BNDED. FN. SLT/CARB. CLAYST.; CSE. SS W/EXT. CALC. CMT.; EXTREME CALCITE W/CARB, CLAY BNDS.; FLASERED & RIPPLED MED-CSE SS/CARB. CLAY W/ EXTREME PY. CMT.; FLASERED & RIPPLED V/FN. SS/ SLT/ CLAYST.; FNLY LAMINATED CARB. CLAY/SLT.; FNLY LAMINATED HIGHLY CARB. CLAYST.; FNLY LAMINATED SLT/CLAY; MED-CSE SS. CALC. & FERRUG. CMT. & SL. PY .; MED-CSE SS. W/CALC. & FERRUG. CMT. & SL. PY.; MED. FN. SS W/FERRUG. & CALC. CLAY MATRIX & SL. PY. CARB. FRAGS.; MED.-CSE SS. EXTREME CALC.CMT.; MED/CSE. SS CLAY MATRIX, CALC. CMT.; SLT. W/ EXT. PY. MARCASLTE & CHALCO PYRITE.; UNIFORM MED.-FN. SS W/FERRUG. CLAY MATRIX.; V. FN. SLT/CLAY W/FN. SS.BNDS. & SL. PY.; V. FN. SLT/CLAY W/THIN CALC. CMT'D FN. SS LAMINAE.; V. FN. SLT/CLAYST. W/V. FN. SS. LAMINAE.; V. FNLY LAMINATED SLT & CARB. CLAYST.; V/FN. SS W/EXTREME SIL. CMT.
|
--
|
| 16/07a- 16 |
↳ Plug AKU1
|
3819.357
|
--
|
φ 20.0% · Kh 289.0 mD · So 13.6% · Sw 29.2% · Density 2.67 · FSP 18.3 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 1
|
3819.357
|
--
|
φ 20.0% · Kh 289.0 mD · So 13.6% · Sw 29.2% · Density 2.67 · FSP 18.3 · REDWOOD COREX (SERVICES) LIMITED
|
UNIFORM MED.-FN. SS W/FERRUG. CLAY MATRIX.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 2
|
3819.784
|
--
|
φ 0.5% · So 28.9% · Sw 43.3% · Density 2.63 · FSP 4.4 · REDWOOD COREX (SERVICES) LIMITED
|
FLASERED & RIPPLED V/FN. SS/ SLT/ CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKU2
|
3819.784
|
--
|
φ 0.5% · So 28.9% · Sw 43.3% · Density 2.63 · FSP 4.4 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKU3
|
3820.18
|
--
|
φ 2.4% · Kh 0.3 mD · So 41.1% · Sw 27.4% · Density 3.74 · FSP 4.5 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 3
|
3820.18
|
--
|
φ 2.4% · Kh 0.3 mD · So 41.1% · Sw 27.4% · Density 3.74 · FSP 4.5 · REDWOOD COREX (SERVICES) LIMITED
|
SLT. W/ EXT. PY. MARCASLTE & CHALCO PYRITE.
|
--
|
| 16/07a- 16 |
↳ Plug AKU4
|
3820.851
|
--
|
φ 1.8% · So 29.3% · Sw 29.3% · Density 2.65 · FSP 3.9 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 4
|
3820.851
|
--
|
φ 1.8% · So 29.3% · Sw 29.3% · Density 2.65 · FSP 3.9 · REDWOOD COREX (SERVICES) LIMITED
|
V/FN. SS W/EXTREME SIL. CMT.
|
--
|
| 16/07a- 16 |
↳ Plug AKU5
|
3821.247
|
--
|
φ 3.0% · So 31.2% · Sw 37.5% · Density 2.53 · FSP 4.7 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 5
|
3821.247
|
--
|
φ 3.0% · So 31.2% · Sw 37.5% · Density 2.53 · FSP 4.7 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED FN. SLT/CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKU6
|
3821.704
|
--
|
φ 0.5% · Kh 0.2 mD · So 33.0% · Sw 26.4% · Density 2.65 · FSP 4.7 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 6
|
3821.704
|
--
|
φ 0.5% · Kh 0.2 mD · So 33.0% · Sw 26.4% · Density 2.65 · FSP 4.7 · REDWOOD COREX (SERVICES) LIMITED
|
EXTREME CALCITE W/CARB, CLAY BNDS.
|
--
|
| 16/07a- 16 |
↳ Plug AKU7
|
3822.131
|
--
|
φ 2.1% · So 24.5% · Sw 24.5% · Density 2.58 · FSP 2.6 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 7
|
3822.131
|
--
|
φ 2.1% · So 24.5% · Sw 24.5% · Density 2.58 · FSP 2.6 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED. FN. SLT/CARB. CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 8
|
3822.68
|
--
|
So 24.8% · Sw 37.3% · FSP 4.9 · REDWOOD COREX (SERVICES) LIMITED
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU8
|
3822.68
|
--
|
So 24.8% · Sw 37.3% · FSP 4.9 · REDWOOD COREX
|
N.P.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 9
|
3823.289
|
--
|
φ 1.8% · Kh 0.4 mD · So 27.4% · Sw 41.0% · Density 2.53 · FSP 4.5 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED. FN. SLT/CARB. CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKU9
|
3823.289
|
--
|
φ 1.8% · Kh 0.4 mD · So 27.4% · Sw 41.0% · Density 2.53 · FSP 4.5 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 10
|
3823.716
|
--
|
φ 1.3% · Kh 0.5 mD · So 28.8% · Sw 40.4% · Density 2.55 · FSP 5.3 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED FN. SLT/CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKU10
|
3823.716
|
--
|
φ 1.3% · Kh 0.5 mD · So 28.8% · Sw 40.4% · Density 2.55 · FSP 5.3 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU11
|
3824.173
|
--
|
φ 1.0% · Kh 0.1 mD · Kv 0.0 mD · So 33.8% · Sw 47.4% · Density 2.50 · FSP 4.5 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 11
|
3824.173
|
--
|
φ 1.0% · Kh 0.1 mD · Kv 0.0 mD · So 33.8% · Sw 47.4% · Density 2.50 · FSP 4.5 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED FN. SLT/CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKU12
|
3824.63
|
--
|
φ 1.2% · So 31.9% · Sw 46.1% · Density 2.51 · FSP 4.4 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 12
|
3824.63
|
--
|
φ 1.2% · So 31.9% · Sw 46.1% · Density 2.51 · FSP 4.4 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED FN. SLT/CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 13
|
3825.088
|
--
|
φ 1.8% · So 25.7% · Sw 51.4% · Density 2.57 · FSP 3.6 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED FN. SLT/CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKU13
|
3825.088
|
--
|
φ 1.8% · So 25.7% · Sw 51.4% · Density 2.57 · FSP 3.6 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 14
|
3825.545
|
--
|
φ 1.3% · So 25.8% · Sw 43.0% · Density 2.61 · FSP 3.6 · REDWOOD COREX (SERVICES) LIMITED
|
V. FN. SLT/CLAY W/THIN CALC. CMT'D FN. SS LAMINAE.
|
--
|
| 16/07a- 16 |
↳ Plug AKU14
|
3825.545
|
--
|
φ 1.3% · So 25.8% · Sw 43.0% · Density 2.61 · FSP 3.6 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 15
|
3826.032
|
--
|
φ 1.0% · Kh 0.4 mD · So 23.1% · Sw 53.9% · Density 2.48 · FSP 4.0 · REDWOOD COREX (SERVICES) LIMITED
|
FNLY LAMINATED HIGHLY CARB. CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKU15
|
3826.032
|
--
|
φ 1.0% · Kh 0.4 mD · So 23.1% · Sw 53.9% · Density 2.48 · FSP 4.0 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU16
|
3826.52
|
--
|
φ 2.0% · So 30.2% · Sw 30.2% · Density 2.59 · FSP 3.1 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 16
|
3826.52
|
--
|
φ 2.0% · So 30.2% · Sw 30.2% · Density 2.59 · FSP 3.1 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED CALC. V.FN. SS/CARB. CLAY.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 17
|
3827.069
|
--
|
φ 0.1% · Kh 0.1 mD · So 37.3% · Sw 9.3% · Density 2.63 · FSP 1.7 · REDWOOD COREX (SERVICES) LIMITED
|
MED. FN. SS W/FERRUG. & CALC. CLAY MATRIX & SL. PY. CARB. FRAGS.
|
--
|
| 16/07a- 16 |
↳ Plug AKU17
|
3827.069
|
--
|
φ 0.1% · Kh 0.1 mD · So 37.3% · Sw 9.3% · Density 2.63 · FSP 1.7 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 18
|
3827.556
|
--
|
φ 0.9% · Kh 0.6 mD · Kv 0.0 mD · So 33.5% · Sw 43.6% · Density 2.55 · FSP 4.7 · REDWOOD COREX (SERVICES) LIMITED
|
FNLY LAMINATED CARB. CLAY/SLT.
|
--
|
| 16/07a- 16 |
↳ Plug AKU18
|
3827.556
|
--
|
φ 0.9% · Kh 0.6 mD · Kv 0.0 mD · So 33.5% · Sw 43.6% · Density 2.55 · FSP 4.7 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 19
|
3827.983
|
--
|
φ 1.4% · Kh 0.8 mD · So 39.3% · Sw 31.4% · Density 2.55 · FSP 3.9 · REDWOOD COREX (SERVICES) LIMITED
|
FNLY LAMINATED CARB. CLAY/SLT.
|
--
|
| 16/07a- 16 |
↳ Plug AKU19
|
3827.983
|
--
|
φ 1.4% · Kh 0.8 mD · So 39.3% · Sw 31.4% · Density 2.55 · FSP 3.9 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU20
|
3828.501
|
--
|
φ 2.5% · Kh 0.2 mD · So 35.5% · Sw 26.6% · Density 3.49 · FSP 3.5 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 20
|
3828.501
|
--
|
φ 2.5% · Kh 0.2 mD · So 35.5% · Sw 26.6% · Density 3.49 · FSP 3.5 · REDWOOD COREX (SERVICES) LIMITED
|
FLASERED & RIPPLED MED-CSE SS/CARB. CLAY W/ EXTREME PY. CMT.
|
--
|
| 16/07a- 16 |
↳ Plug AKU21
|
3828.959
|
--
|
φ 0.9% · Kh 0.1 mD · So 39.6% · Sw 19.8% · Density 2.67 · FSP 1.7 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 21
|
3828.959
|
--
|
φ 0.9% · Kh 0.1 mD · So 39.6% · Sw 19.8% · Density 2.67 · FSP 1.7 · REDWOOD COREX (SERVICES) LIMITED
|
MED.-CSE SS. EXTREME CALC.CMT.
|
--
|
| 16/07a- 16 |
↳ Plug AKU22
|
3829.233
|
--
|
φ 1.2% · Kh 0.2 mD · So 12.9% · Sw 6.4% · Density 2.68 · FSP 2.5 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 22
|
3829.233
|
--
|
φ 1.2% · Kh 0.2 mD · So 12.9% · Sw 6.4% · Density 2.68 · FSP 2.5 · REDWOOD COREX (SERVICES) LIMITED
|
MED.-CSE SS. EXTREME CALC.CMT.
|
--
|
| 16/07a- 16 |
↳ Plug AKU23
|
3829.812
|
--
|
φ 0.9% · Kh 0.7 mD · So 30.6% · Sw 30.6% · Density 2.55 · FSP 3.0 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 23
|
3829.812
|
--
|
φ 0.9% · Kh 0.7 mD · So 30.6% · Sw 30.6% · Density 2.55 · FSP 3.0 · REDWOOD COREX (SERVICES) LIMITED
|
V. FN. SLT/CLAY W/FN. SS.BNDS. & SL. PY.
|
--
|
| 16/07a- 16 |
↳ Plug AKU24
|
3830.269
|
--
|
φ 0.4% · Kh 0.1 mD · So 26.8% · Sw 26.8% · Density 2.51 · FSP 3.4 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 24
|
3830.269
|
--
|
φ 0.4% · Kh 0.1 mD · So 26.8% · Sw 26.8% · Density 2.51 · FSP 3.4 · REDWOOD COREX (SERVICES) LIMITED
|
FNLY LAMINATED SLT/CLAY
|
--
|
| 16/07a- 16 |
↳ Plug AKU25
|
3830.879
|
--
|
φ 3.2% · Kh 2.0 mD · Kv 0.1 mD · So 25.5% · Sw 12.7% · Density 2.59 · FSP 2.5 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 25
|
3830.879
|
--
|
φ 3.2% · Kh 2.0 mD · Kv 0.1 mD · So 25.5% · Sw 12.7% · Density 2.59 · FSP 2.5 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED V/FN. SS & SLT/CLAY
|
--
|
| 16/07a- 16 |
↳ Plug AKU26
|
3831.245
|
--
|
φ 2.2% · Kh 0.2 mD · So 22.4% · Sw 29.8% · Density 2.70 · FSP 4.2 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 26
|
3831.245
|
--
|
φ 2.2% · Kh 0.2 mD · So 22.4% · Sw 29.8% · Density 2.70 · FSP 4.2 · REDWOOD COREX (SERVICES) LIMITED
|
MED-CSE SS. W/CALC. & FERRUG. CMT. & SL. PY.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 27
|
3831.793
|
--
|
φ 0.7% · Kh 0.1 mD · So 23.6% · Sw 39.3% · Density 2.50 · FSP 3.9 · REDWOOD COREX (SERVICES) LIMITED
|
V. FNLY LAMINATED SLT & CARB. CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKU27
|
3831.793
|
--
|
φ 0.7% · Kh 0.1 mD · So 23.6% · Sw 39.3% · Density 2.50 · FSP 3.9 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 28
|
3832.342
|
--
|
φ 1.3% · So 21.1% · Sw 35.1% · Density 2.54 · FSP 4.2 · REDWOOD COREX (SERVICES) LIMITED
|
V. FNLY LAMINATED SLT & CARB. CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKU28
|
3832.342
|
--
|
φ 1.3% · So 21.1% · Sw 35.1% · Density 2.54 · FSP 4.2 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 29
|
3832.89
|
--
|
φ 1.1% · Kh 0.1 mD · So 34.0% · Sw 13.6% · Density 2.69 · FSP 2.4 · REDWOOD COREX (SERVICES) LIMITED
|
MED-CSE SS. CALC. & FERRUG. CMT. & SL. PY .
|
--
|
| 16/07a- 16 |
↳ Plug AKU29
|
3832.89
|
--
|
φ 1.1% · Kh 0.1 mD · So 34.0% · Sw 13.6% · Density 2.69 · FSP 2.4 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU30
|
3833.348
|
--
|
φ 0.7% · Kh 0.3 mD · So 20.4% · Sw 40.7% · Density 2.54 · FSP 4.5 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 30
|
3833.348
|
--
|
φ 0.7% · Kh 0.3 mD · So 20.4% · Sw 40.7% · Density 2.54 · FSP 4.5 · REDWOOD COREX (SERVICES) LIMITED
|
V. FN. SLT/CLAYST. W/V. FN. SS. LAMINAE.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 31
|
3833.835
|
--
|
φ 1.1% · Kh 0.6 mD · So 32.4% · Sw 37.1% · Density 2.54 · FSP 3.4 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED V. FN. SLT. CARB. CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKU31
|
3833.835
|
--
|
φ 1.1% · Kh 0.6 mD · So 32.4% · Sw 37.1% · Density 2.54 · FSP 3.4 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU32
|
3834.414
|
--
|
φ 0.2% · Kh 0.1 mD · Kv 0.1 mD · So 31.4% · Sw 44.8% · Density 2.55 · FSP 3.5 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 32
|
3834.414
|
--
|
φ 0.2% · Kh 0.1 mD · Kv 0.1 mD · So 31.4% · Sw 44.8% · Density 2.55 · FSP 3.5 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED SLT/CLAY W/BRECCIA MAT.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 33
|
3835.085
|
--
|
φ 2.1% · So 52.9% · Sw 10.6% · Density 2.59 · FSP 4.5 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED V/FN. SS/SLT/CLAY
|
--
|
| 16/07a- 16 |
↳ Plug AKU33
|
3835.085
|
--
|
φ 2.1% · So 52.9% · Sw 10.6% · Density 2.59 · FSP 4.5 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKU34
|
3835.542
|
--
|
φ 3.5% · Kh 0.2 mD · So 45.4% · Sw 25.2% · Density 2.66 · FSP 6.0 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 34
|
3835.542
|
--
|
φ 3.5% · Kh 0.2 mD · So 45.4% · Sw 25.2% · Density 2.66 · FSP 6.0 · REDWOOD COREX (SERVICES) LIMITED
|
MED/CSE. SS CLAY MATRIX, CALC. CMT.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 35
|
3836.091
|
--
|
φ 2.9% · So 24.8% · Sw 42.6% · Density 2.61 · FSP 4.5 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED SLT/CLAY & FN. BRECCIA
|
--
|
| 16/07a- 16 |
↳ Plug AKU35
|
3836.091
|
--
|
φ 2.9% · So 24.8% · Sw 42.6% · Density 2.61 · FSP 4.5 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKU36
|
3836.487
|
--
|
φ 1.4% · Kh 0.1 mD · So 23.7% · Sw 15.8% · Density 2.68 · FSP 2.1 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 36
|
3836.487
|
--
|
φ 1.4% · Kh 0.1 mD · So 23.7% · Sw 15.8% · Density 2.68 · FSP 2.1 · REDWOOD COREX (SERVICES) LIMITED
|
CSE. SS W/EXT. CALC. CMT.
|
--
|
| 16/07a- 16 |
↳ Plug AKU 37
|
3837.158
|
--
|
φ 2.5% · Kh 0.1 mD · So 20.0% · Sw 13.3% · Density 2.69 · FSP 2.4 · REDWOOD COREX (SERVICES) LIMITED
|
CSE. SS W/EXT. CALC. CMT.
|
--
|
| 16/07a- 16 |
↳ Plug AKU37
|
3837.158
|
--
|
φ 2.5% · Kh 0.1 mD · So 20.0% · Sw 13.3% · Density 2.69 · FSP 2.4 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU38
|
3837.92
|
--
|
φ 1.9% · Kh 0.1 mD · So 17.5% · Sw 7.0% · Density 2.68 · FSP 2.3 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKU 38
|
3837.92
|
--
|
φ 1.9% · Kh 0.1 mD · So 17.5% · Sw 7.0% · Density 2.68 · FSP 2.3 · REDWOOD COREX (SERVICES) LIMITED
|
CSE. SS W/EXT. CALC. CMT.
|
--
|
| 16/07a- 16 |
Core #5
|
3838.71
|
3845.3
|
φ 1.9% (n=16) · Kh 0.3 mD (n=16) · So 26.3% (n=16) · Sw 32.6% (n=16) · Density 2.58 (n=16) · FSP 4.0 (n=16) · REDWOOD COREX (SERVICES) LIMITED
|
BNDED V. FN. SS/SLT/CLAY; BNDED V. FN. SS/SLT/CLAY. W/LOAD STRUCTURES; BRECCIA MATERIAL (METAMORPHIC); CSE SS SL. CALC. CMT. LARGE FRAGS, OF BRECCIATED SLT.; FLASER/LOAD STRUCTURED SS/ SLT/CLAY; FLASERED MED-CSE. SS/SLT/ CLAY.; SLT/CLAYST. BRECCIA
|
--
|
| 16/07a- 16 |
↳ Plug AKV 1
|
3838.804
|
--
|
φ 5.1% · Kh 0.4 mD · So 16.5% · Sw 11.0% · Density 2.69 · FSP 2.8 · REDWOOD COREX (SERVICES) LIMITED
|
CSE SS SL. CALC. CMT. LARGE FRAGS, OF BRECCIATED SLT.
|
--
|
| 16/07a- 16 |
↳ Plug AKV1
|
3838.804
|
--
|
φ 5.1% · Kh 0.4 mD · So 16.5% · Sw 11.0% · Density 2.69 · FSP 2.8 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKV 2
|
3839.108
|
--
|
φ 0.2% · Kh 0.1 mD · So 39.3% · Sw 14.8% · Density 2.63 · FSP 3.1 · REDWOOD COREX (SERVICES) LIMITED
|
BRECCIA MATERIAL (METAMORPHIC)
|
--
|
| 16/07a- 16 |
↳ Plug AKV2
|
3839.108
|
--
|
φ 0.2% · Kh 0.1 mD · So 39.3% · Sw 14.8% · Density 2.63 · FSP 3.1 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKV3
|
3839.566
|
--
|
φ 2.0% · Kh 0.5 mD · So 26.9% · Sw 41.9% · Density 2.56 · FSP 5.0 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKV 3
|
3839.566
|
--
|
φ 2.0% · Kh 0.5 mD · So 26.9% · Sw 41.9% · Density 2.56 · FSP 5.0 · REDWOOD COREX (SERVICES) LIMITED
|
FLASERED MED-CSE. SS/SLT/ CLAY.
|
--
|
| 16/07a- 16 |
↳ Plug AKV 4
|
3839.931
|
--
|
φ 1.8% · Kh 0.2 mD · So 31.2% · Sw 37.4% · Density 2.54 · FSP 5.1 · REDWOOD COREX (SERVICES) LIMITED
|
SLT/CLAYST. BRECCIA
|
--
|
| 16/07a- 16 |
↳ Plug AKV4
|
3839.931
|
--
|
φ 1.8% · Kh 0.2 mD · So 31.2% · Sw 37.4% · Density 2.54 · FSP 5.1 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKV 5
|
3840.145
|
--
|
φ 2.1% · Kh 0.1 mD · So 29.5% · Sw 36.9% · Density 2.55 · FSP 4.2 · REDWOOD COREX (SERVICES) LIMITED
|
SLT/CLAYST. BRECCIA
|
--
|
| 16/07a- 16 |
↳ Plug AKV5
|
3840.145
|
--
|
φ 2.1% · Kh 0.1 mD · So 29.5% · Sw 36.9% · Density 2.55 · FSP 4.2 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKV 6
|
3840.785
|
--
|
φ 1.4% · Kh 0.1 mD · So 30.1% · Sw 37.7% · Density 2.57 · FSP 4.0 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED V. FN. SS/SLT/CLAY
|
--
|
| 16/07a- 16 |
↳ Plug AKV6
|
3840.785
|
--
|
φ 1.4% · Kh 0.1 mD · So 30.1% · Sw 37.7% · Density 2.57 · FSP 4.0 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKV 7
|
3841.699
|
--
|
φ 1.0% · Kh 0.7 mD · So 22.6% · Sw 37.6% · Density 2.54 · FSP 3.9 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED V. FN. SS/SLT/CLAY. W/LOAD STRUCTURES
|
--
|
| 16/07a- 16 |
↳ Plug AKV7
|
3841.699
|
--
|
φ 1.0% · Kh 0.7 mD · So 22.6% · Sw 37.6% · Density 2.54 · FSP 3.9 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKV8
|
3844.442
|
--
|
φ 1.2% · Kh 0.2 mD · So 14.5% · Sw 43.5% · Density 2.52 · FSP 4.2 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKV 8
|
3844.442
|
--
|
φ 1.2% · Kh 0.2 mD · So 14.5% · Sw 43.5% · Density 2.52 · FSP 4.2 · REDWOOD COREX (SERVICES) LIMITED
|
FLASER/LOAD STRUCTURED SS/ SLT/CLAY
|
--
|
| 16/07a- 16 |
Core #6
|
3846.94
|
3851.3
|
REDWOOD COREX
|
NO ANALYSIS
|
--
|
| 16/07a- 16 |
↳ Core Plug #6
|
3846.942
|
--
|
REDWOOD COREX
|
NO ANALYSIS
|
--
|
| 16/07a- 16 |
↳ Core Plug #6
|
3850.691
|
--
|
REDWOOD COREX
|
NO ANALYSIS
|
--
|
| 16/07a- 16 |
↳ Core Plug #6
|
3851.148
|
--
|
REDWOOD COREX
|
NO ANALYSIS
|
--
|
| 16/07a- 16 |
Core #7
|
3851.15
|
3860.2
|
--
|
--
|
--
|
| 16/07a- 16 |
Core #8
|
3861.82
|
3889.25
|
φ 4.1% (n=32) · Kh 1.2 mD (n=20) · Kv 0.4 mD (n=4) · So 24.8% (n=32) · Sw 32.9% (n=32) · Density 2.63 (n=32) · FSP 4.8 (n=32) · REDWOOD COREX (SERVICES) LIMITED
|
S.P. | BNDED SLT/CLAYST.; BNDED V. FN. SS/SLT/CLAY; FN. SS. W/SL. CALC. CMT.; MED-CSE. SS, EXT. CALC. CMT. & PY.; MED. CSE SS. CALC. CMT. & CLAYST. BND.; SLTST W/CALC. CMT.; V. CSE. SS/BRECCIA.FERRUG. W/ CALC. CMT. & SL. PY.; V. FN. SS. SL. CALC. CMT. SL. CLAY
|
--
|
| 16/07a- 16 |
↳ Plug AKZ 1
|
3863.34
|
--
|
φ 3.9% · So 41.4% · Sw 51.7% · Density 2.56 · FSP 2.8 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED V. FN. SS/SLT/CLAY
|
--
|
| 16/07a- 16 |
↳ Plug AKZ1
|
3863.34
|
--
|
φ 3.9% · So 41.4% · Sw 51.7% · Density 2.56 · FSP 2.8 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKZ 2
|
3864.955
|
--
|
φ 4.6% · Kh 1.9 mD · So 33.8% · Sw 40.6% · Density 2.55 · FSP 4.4 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED V. FN. SS/SLT/CLAY
|
--
|
| 16/07a- 16 |
↳ Plug AKZ2
|
3864.955
|
--
|
φ 4.6% · Kh 1.9 mD · So 33.8% · Sw 40.6% · Density 2.55 · FSP 4.4 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKZ3
|
3866.388
|
--
|
φ 3.0% · Kv 0.3 mD · So 29.9% · Sw 37.4% · Density 2.60 · FSP 4.0 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKZ 3
|
3866.388
|
--
|
φ 3.0% · Kv 0.3 mD · So 29.9% · Sw 37.4% · Density 2.60 · FSP 4.0 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED V. FN. SS/SLT/CLAY
|
--
|
| 16/07a- 16 |
↳ Plug AKZ4
|
3869.436
|
--
|
φ 1.4% · So 24.6% · Sw 32.8% · Density 2.56 · FSP 3.8 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKZ 4
|
3869.436
|
--
|
φ 1.4% · So 24.6% · Sw 32.8% · Density 2.56 · FSP 3.8 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED V. FN. SS/SLT/CLAY
|
--
|
| 16/07a- 16 |
↳ Plug AKZ5
|
3871.204
|
--
|
φ 3.1% · Kh 1.2 mD · So 31.1% · Sw 38.8% · Density 2.58 · FSP 4.0 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKZ 5
|
3871.204
|
--
|
φ 3.1% · Kh 1.2 mD · So 31.1% · Sw 38.8% · Density 2.58 · FSP 4.0 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED V. FN. SS/SLT/CLAY
|
--
|
| 16/07a- 16 |
↳ Plug AKZ6
|
3874.099
|
--
|
φ 2.5% · So 27.0% · Sw 40.4% · Density 2.62 · FSP 6.9 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKZ 6
|
3874.099
|
--
|
φ 2.5% · So 27.0% · Sw 40.4% · Density 2.62 · FSP 6.9 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED V. FN. SS/SLT/CLAY
|
--
|
| 16/07a- 16 |
↳ Plug AKZ 7
|
3875.441
|
--
|
φ 1.3% · Kh 0.5 mD · So 24.4% · Sw 24.4% · Density 2.78 · FSP 2.3 · REDWOOD COREX (SERVICES) LIMITED
|
MED-CSE. SS, EXT. CALC. CMT. & PY.
|
--
|
| 16/07a- 16 |
↳ Plug AKZ7
|
3875.441
|
--
|
φ 1.3% · Kh 0.5 mD · So 24.4% · Sw 24.4% · Density 2.78 · FSP 2.3 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKZ8
|
3877.117
|
--
|
φ 5.1% · Kv 0.5 mD · So 25.0% · Sw 33.3% · Density 2.67 · FSP 3.5 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKZ 8
|
3877.117
|
--
|
φ 5.1% · Kv 0.5 mD · So 25.0% · Sw 33.3% · Density 2.67 · FSP 3.5 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED V. FN. SS/SLT/CLAY
|
--
|
| 16/07a- 16 |
↳ Plug AKZ 9
|
3881.963
|
--
|
φ 1.8% · So 35.6% · Sw 35.6% · Density 2.66 · FSP 1.7 · REDWOOD COREX (SERVICES) LIMITED
|
MED. CSE SS. CALC. CMT. & CLAYST. BND.
|
--
|
| 16/07a- 16 |
↳ Plug AKZ9
|
3881.963
|
--
|
φ 1.8% · So 35.6% · Sw 35.6% · Density 2.66 · FSP 1.7 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug AKZ 10
|
3883.304
|
--
|
φ 5.7% · Kh 1.6 mD · So 27.4% · Sw 41.0% · Density 2.63 · FSP 4.2 · REDWOOD COREX (SERVICES) LIMITED
|
SLTST W/CALC. CMT.
|
--
|
| 16/07a- 16 |
↳ Plug AKZ10
|
3883.304
|
--
|
φ 5.7% · Kh 1.6 mD · So 27.4% · Sw 41.0% · Density 2.63 · FSP 4.2 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKZ 11
|
3885.56
|
--
|
φ 3.3% · Kh 1.6 mD · So 22.2% · Sw 22.2% · Density 2.70 · FSP 1.5 · REDWOOD COREX (SERVICES) LIMITED
|
V. CSE. SS/BRECCIA.FERRUG. W/ CALC. CMT. & SL. PY.
|
--
|
| 16/07a- 16 |
↳ Plug AKZ11
|
3885.56
|
--
|
φ 3.3% · Kh 1.6 mD · So 22.2% · Sw 22.2% · Density 2.70 · FSP 1.5 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKZ12
|
3886.23
|
--
|
φ 1.3% · Kh 0.6 mD · So 31.6% · Sw 44.2% · Density 2.54 · FSP 4.5 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKZ 12
|
3886.23
|
--
|
φ 1.3% · Kh 0.6 mD · So 31.6% · Sw 44.2% · Density 2.54 · FSP 4.5 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED SLT/CLAYST.
|
--
|
| 16/07a- 16 |
↳ Plug AKZ 13
|
3886.992
|
--
|
φ 2.6% · Kh 0.7 mD · So 18.3% · Sw 18.3% · Density 2.62 · FSP 3.3 · REDWOOD COREX (SERVICES) LIMITED
|
V. FN. SS. SL. CALC. CMT. SL. CLAY
|
--
|
| 16/07a- 16 |
↳ Plug AKZ13
|
3886.992
|
--
|
φ 2.6% · Kh 0.7 mD · So 18.3% · Sw 18.3% · Density 2.62 · FSP 3.3 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKZ14
|
3888.395
|
--
|
φ 8.6% · Kh 1.4 mD · So 8.9% · Sw 20.4% · Density 2.66 · FSP 11.1 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKZ 14
|
3888.395
|
--
|
φ 8.6% · Kh 1.4 mD · So 8.9% · Sw 20.4% · Density 2.66 · FSP 11.1 · REDWOOD COREX (SERVICES) LIMITED
|
FN. SS. W/SL. CALC. CMT.
|
--
|
| 16/07a- 16 |
↳ Plug AKZ15
|
3888.577
|
--
|
φ 9.3% · Kh 1.7 mD · So 4.9% · Sw 16.5% · Density 2.66 · FSP 8.6 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKZ 15
|
3888.577
|
--
|
φ 9.3% · Kh 1.7 mD · So 4.9% · Sw 16.5% · Density 2.66 · FSP 8.6 · REDWOOD COREX (SERVICES) LIMITED
|
FN. SS. W/SL. CALC. CMT.
|
--
|
| 16/07a- 16 |
↳ Plug AKZ16
|
3888.974
|
--
|
φ 7.5% · Kh 1.3 mD · So 10.2% · Sw 28.2% · Density 2.66 · FSP 10.8 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug AKZ 16
|
3888.974
|
--
|
φ 7.5% · Kh 1.3 mD · So 10.2% · Sw 28.2% · Density 2.66 · FSP 10.8 · REDWOOD COREX (SERVICES) LIMITED
|
FN. SS. W/SL. CALC. CMT.
|
--
|
| 16/07a- 16 |
Core #9
|
3889.25
|
3900.46
|
φ 7.2% (n=34) · Kh 4.7 mD (n=28) · Kv 0.7 mD (n=4) · So 18.6% (n=36) · Sw 30.1% (n=36) · Density 2.64 (n=34) · FSP 7.3 (n=36) · REDWOOD COREX (SERVICES) LIMITED
|
N.P.P.; S.P. | BNDED FN. SS/SLT/CLAY.; BNDED. V. FN. SS/SLT/CLAY; FN-V.FN. SS. W/CLAY VEINING.; FN./V. FN. SS. SL. CLAY MATRIX; FN/V. FN. SS. SL. CLAY MATRIX & CALC. CMT. & CLAY VEINING; LAMINATED V. FN. SS/SLT/CLAY; UNIFORM FN-GRND. SS. SIL. CMT.; V. FN. GRND. SS, W/CARB. CLAY LAMINATIONS; V. FN. SS W/EXT. CALC CMT.; V. FN. SS W/FN. CLAY BNDING.; V. FN. SS. CALC. CMT. & CARB. CLAY BNDS.; V. FN. SS. W/CALC. CMT.; V. FN. SS. W/CLAYST. LAMINATION
|
--
|
| 16/07a- 16 |
↳ Plug ALA1
|
3889.309
|
--
|
φ 9.2% · Kv 0.6 mD · So 18.3% · Sw 22.8% · Density 2.68 · FSP 6.7 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug ALA 1
|
3889.309
|
--
|
φ 9.2% · Kv 0.6 mD · So 18.3% · Sw 22.8% · Density 2.68 · FSP 6.7 · REDWOOD COREX (SERVICES) LIMITED
|
V. FN. GRND. SS, W/CARB. CLAY LAMINATIONS
|
--
|
| 16/07a- 16 |
↳ Plug ALA 2
|
3889.614
|
--
|
φ 2.5% · Kh 0.4 mD · So 23.1% · Sw 27.7% · Density 2.68 · FSP 3.5 · REDWOOD COREX (SERVICES) LIMITED
|
V. FN. SS. W/CALC. CMT.
|
--
|
| 16/07a- 16 |
↳ Plug ALA2
|
3889.614
|
--
|
φ 2.5% · Kh 0.4 mD · So 23.1% · Sw 27.7% · Density 2.68 · FSP 3.5 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug ALA 3
|
3889.736
|
--
|
φ 6.4% · Kh 1.7 mD · So 21.0% · Sw 52.5% · Density 2.63 · FSP 4.2 · REDWOOD COREX (SERVICES) LIMITED
|
V. FN. SS. W/CLAYST. LAMINATION
|
--
|
| 16/07a- 16 |
↳ Plug ALA3
|
3889.736
|
--
|
φ 6.4% · Kh 1.7 mD · So 21.0% · Sw 52.5% · Density 2.63 · FSP 4.2 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug ALA 4
|
3889.919
|
--
|
φ 14.8% · Kh 42.7 mD · So 13.8% · Sw 31.0% · Density 2.66 · FSP 15.7 · REDWOOD COREX (SERVICES) LIMITED
|
UNIFORM FN-GRND. SS. SIL. CMT.
|
--
|
| 16/07a- 16 |
↳ Plug ALA4
|
3889.919
|
--
|
φ 14.8% · Kh 42.7 mD · So 13.8% · Sw 31.0% · Density 2.66 · FSP 15.7 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug ALA 5
|
3890.223
|
--
|
φ 14.7% · Kh 9.2 mD · So 15.1% · Sw 26.5% · Density 2.65 · FSP 14.8 · REDWOOD COREX (SERVICES) LIMITED
|
FN./V. FN. SS. SL. CLAY MATRIX
|
--
|
| 16/07a- 16 |
↳ Plug ALA5
|
3890.223
|
--
|
φ 14.7% · Kh 9.2 mD · So 15.1% · Sw 26.5% · Density 2.65 · FSP 14.8 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug ALA 6
|
3890.528
|
--
|
φ 0.8% · Kh 0.5 mD · So 27.6% · Sw 33.2% · Density 2.50 · FSP 5.4 · REDWOOD COREX (SERVICES) LIMITED
|
LAMINATED V. FN. SS/SLT/CLAY
|
--
|
| 16/07a- 16 |
↳ Plug ALA6
|
3890.528
|
--
|
φ 0.8% · Kh 0.5 mD · So 27.6% · Sw 33.2% · Density 2.50 · FSP 5.4 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug ALA 7
|
3890.833
|
--
|
φ 5.0% · So 30.2% · Sw 35.2% · Density 2.62 · FSP 6.1 · REDWOOD COREX (SERVICES) LIMITED
|
V. FN. SS W/FN. CLAY BNDING.
|
--
|
| 16/07a- 16 |
↳ Plug ALA7
|
3890.833
|
--
|
φ 5.0% · So 30.2% · Sw 35.2% · Density 2.62 · FSP 6.1 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug ALA 8
|
3891.107
|
--
|
φ 1.6% · Kh 0.3 mD · So 17.8% · Sw 26.8% · Density 2.68 · FSP 3.6 · REDWOOD COREX (SERVICES) LIMITED
|
V. FN. SS W/EXT. CALC CMT.
|
--
|
| 16/07a- 16 |
↳ Plug ALA8
|
3891.107
|
--
|
φ 1.6% · Kh 0.3 mD · So 17.8% · Sw 26.8% · Density 2.68 · FSP 3.6 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug ALA9
|
3891.443
|
--
|
φ 9.7% · Kh 1.6 mD · So 17.2% · Sw 34.5% · Density 2.65 · FSP 11.5 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug ALA 9
|
3891.443
|
--
|
φ 9.7% · Kh 1.6 mD · So 17.2% · Sw 34.5% · Density 2.65 · FSP 11.5 · REDWOOD COREX (SERVICES) LIMITED
|
FN-V.FN. SS. W/CLAY VEINING.
|
--
|
| 16/07a- 16 |
↳ Plug ALA10
|
3891.747
|
--
|
φ 9.8% · Kh 1.3 mD · So 10.0% · Sw 40.0% · Density 2.65 · FSP 8.8 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug ALA 10
|
3891.747
|
--
|
φ 9.8% · Kh 1.3 mD · So 10.0% · Sw 40.0% · Density 2.65 · FSP 8.8 · REDWOOD COREX (SERVICES) LIMITED
|
FN-V.FN. SS. W/CLAY VEINING.
|
--
|
| 16/07a- 16 |
↳ Plug ALA11
|
3892.052
|
--
|
φ 9.1% · Kh 2.1 mD · Kv 0.7 mD · So 14.8% · Sw 37.1% · Density 2.65 · FSP 11.6 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug ALA 11
|
3892.052
|
--
|
φ 9.1% · Kh 2.1 mD · Kv 0.7 mD · So 14.8% · Sw 37.1% · Density 2.65 · FSP 11.6 · REDWOOD COREX (SERVICES) LIMITED
|
FN-V.FN. SS. W/CLAY VEINING.
|
--
|
| 16/07a- 16 |
↳ Plug ALA 12
|
3892.936
|
--
|
φ 5.3% · So 28.8% · Sw 38.4% · Density 2.58 · FSP 6.1 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED FN. SS/SLT/CLAY.
|
--
|
| 16/07a- 16 |
↳ Plug ALA12
|
3892.936
|
--
|
φ 5.3% · So 28.8% · Sw 38.4% · Density 2.58 · FSP 6.1 · REDWOOD COREX
|
S.P.
|
--
|
| 16/07a- 16 |
↳ Plug ALA13
|
3894.765
|
--
|
φ 10.5% · Kh 1.1 mD · So 21.1% · Sw 33.8% · Density 2.63 · FSP 7.0 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug ALA 13
|
3894.765
|
--
|
φ 10.5% · Kh 1.1 mD · So 21.1% · Sw 33.8% · Density 2.63 · FSP 7.0 · REDWOOD COREX (SERVICES) LIMITED
|
FN/V. FN. SS. SL. CLAY MATRIX & CALC. CMT. & CLAY VEINING
|
--
|
| 16/07a- 16 |
↳ Plug ALA 14
|
3895.954
|
--
|
φ 10.5% · Kh 1.9 mD · So 15.4% · Sw 21.1% · Density 2.65 · FSP 7.7 · REDWOOD COREX (SERVICES) LIMITED
|
FN/V. FN. SS. SL. CLAY MATRIX & CALC. CMT. & CLAY VEINING
|
--
|
| 16/07a- 16 |
↳ Plug ALA14
|
3895.954
|
--
|
φ 10.5% · Kh 1.9 mD · So 15.4% · Sw 21.1% · Density 2.65 · FSP 7.7 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug ALA 15
|
3896.929
|
--
|
φ 6.9% · Kh 1.1 mD · So 12.9% · Sw 22.6% · Density 2.64 · FSP 4.7 · REDWOOD COREX (SERVICES) LIMITED
|
FN/V. FN. SS. SL. CLAY MATRIX & CALC. CMT. & CLAY VEINING
|
--
|
| 16/07a- 16 |
↳ Plug ALA15
|
3896.929
|
--
|
φ 6.9% · Kh 1.1 mD · So 12.9% · Sw 22.6% · Density 2.64 · FSP 4.7 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug ALA16
|
3898.026
|
--
|
φ 3.5% · Kh 1.2 mD · So 15.9% · Sw 7.9% · Density 2.61 · FSP 3.9 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
↳ Plug ALA 16
|
3898.026
|
--
|
φ 3.5% · Kh 1.2 mD · So 15.9% · Sw 7.9% · Density 2.61 · FSP 3.9 · REDWOOD COREX (SERVICES) LIMITED
|
BNDED. V. FN. SS/SLT/CLAY
|
--
|
| 16/07a- 16 |
↳ Plug ALA17
|
3899.063
|
--
|
So 6.3% · Sw 8.4% · FSP 7.0 · REDWOOD COREX
|
N.P.P.
|
--
|
| 16/07a- 16 |
↳ Plug ALA 17
|
3899.063
|
--
|
So 6.3% · Sw 8.4% · FSP 7.0 · REDWOOD COREX (SERVICES) LIMITED
|
--
|
--
|
| 16/07a- 16 |
↳ Plug ALA 18
|
3899.977
|
--
|
φ 1.6% · Kh 0.5 mD · So 25.4% · Sw 42.4% · Density 2.65 · FSP 3.4 · REDWOOD COREX (SERVICES) LIMITED
|
V. FN. SS. CALC. CMT. & CARB. CLAY BNDS.
|
--
|
| 16/07a- 16 |
↳ Plug ALA18
|
3899.977
|
--
|
φ 1.6% · Kh 0.5 mD · So 25.4% · Sw 42.4% · Density 2.65 · FSP 3.4 · REDWOOD COREX
|
--
|
--
|
| 16/07a- 16 |
Core #10
|
3901.44
|
3916.92
|
REDWOOD COREX (SERVICES) LIMITED
|
NO ANALYSIS | NO ANALYSLS REQUIRED
|
--
|
| 16/07a- 16 |
↳ Core Plug #10
|
3901.44
|
--
|
REDWOOD COREX
|
NO ANALYSIS
|
--
|
| 16/07a- 16 |
↳ Plug ALB
|
3901.44
|
--
|
REDWOOD COREX (SERVICES) LIMITED
|
NO ANALYSLS REQUIRED
|
--
|